J. NON-SYNERGIC PULSE OPERATION
The MultiPower 460 Pulse has the unique ability to Pulse MIG weld in the NON-
SYNERGIC mode. Non-synergic operation means the pulse parameters can
be selected by choosing the WIRE TYPE, WIRE DIAMETER, and presetting
a WIRE FEED SPEED on the MultiPower 460 Pulse panel. The pulse
frequency or arc length (TRIM) is controlled by the TRIM knob. The TRIM knob
is adjustable from the minimum to maximum pulse frequency. By using a
combination of adjusting the wire feed speed on the wire feeder and TRIM
setting on the MultiPower 460 Pulse, the pulse Mig welding arc can be tune in
and stabilized.
The selectable pulse parameters are any combination of WIRE TYPE or WIRE
DIAMETER selected using the PULSE SELECTION switches. Not all combi-
nations will produce acceptable pulse characteristics but by using the pulse
tables provided in this manual, reasonable pulse combinations can be selected
for trial. This will take some trial and error but the added flexibility and
expanded pulse range of the non-synergic mode can be beneficial for many
welding applications.
There are several unique advantages to Non Synergic pulse mig welding. The
Non -Synergic mode of operation permits pulse welding when:
1. A wire feeder without tachometer feedback is used.
2. An "Off the Arc" wire feeder is used
3. The Mig wire type or diameter installed on the wire feeder does not have
a pulse synergic line available..
4. Pulse arc characteristics other than those preprogrammed are desired.
To take advantage of the MultiPower 460 Pulse Non-Synergic mode, it is
necessary to reposition a jumper plug and/or connector in the main control
panel wiring harness. Remove the MultiPower 460 control panel and locate the
jumper plug in the wiring harness in the PC board compartment.
Jumper Plug Installed (Factory Shipped)
Synergic Mode - Pulse circuitry is looking for a 1 volt per 100 inches per minute
signal to determine the pulse parameters required to make the weld.
Jumper Plug Removed and Harness connected
Non-Synergic Mode - The pulse parameters are determined by the position
of the pulse selection switches, the MultiPower 460 Pulse TRIM knob and Wire
Feed Speed preset.
SECTION 3 OPERATION
Figure 4-3
Jumper Plug Installed
(Factory Shipped)
Figure 4-4
Jumper Plug Removed
and Harness Connected
Vista de pagina 17