SECTION 5
MAINTENANCE
If this power source does not op-
erate properly, stop work imme-
diately and investigate the cause
of the malfunction. Maintenance
work must be performed by an
experienced person, and electri-
cal work by a trained electrician.
Do not permit untrained persons
to inspect, clean, or repair this
power source. Use only recom-
mended replacement parts.
Be sure that the branch circuit or
main disconnect switch is off, or
electrical input fuses are removed,
before attempting any inspection
or work inside the power source.
Placing the power switch in the off
position does not remove all power
from inside the power source.
Failure to replace worn or dam-
aged cables may result in a bare
cable touching a grounded object.
The resulting electrical arc may
injure unprotected eyes and will
present a serious fire hazard.
Body contact with a bare cable,
connector, or conductor may re-
sult in severe electrical shock,
causing serious burns or death.
5.0. CLEANING
Periodically, remove the cover from the power source and blow accumulated
dust and dirt from the air passages and interior components by using clean low
pressure air. The frequency of cleaning required depends upon the environment
in which the power source is used.
It is imperative that all air passages be kept as clean as possible in order to
allow adequate air flow to provide proper cooling.
After cleaning with low pressure air, check for and tighten any loose hardware,
including all electrical connections. Check for frayed and/or cracked insulation
on all power cables and replace if necessary.
A. INSPECTION AND SERVICE
Keep the power source dry, free of oil and grease, and protected at all times
from damage by hot metal and sparks.
1. FAN MOTOR
Keep the fan motor free of accumulated dust and lint.
2. TRANSFORMER
Other than periodically cleaning the dust and dirt from the transformer, no
maintenance is required. Ensure that only clean, dry, low pressure air is
used.
3. WIRE FEEDER CONTROL CIRCUITS
These circuits are protected by two 10 amp circuit breakers mounted in the
front panel. If these open, the contactor and wire feeder will not operate.
4. OVER TEMPERATURE PROTECTION
If the power source reaches an abnormally high internal temperature, the
thermal protection will deenergize the contactor circuit, shutting down the
power source but leaving the cooling fan on. After the power source has
cooled to a safe level, the thermal protection will automatically reset. While
de-energized, the contactor and wire feeder cannot be operated.