ESAB MultiPower 460 Pulse Manual de instrucciones

Busca en linea o descarga Manual de instrucciones para Sistema De Soldadura ESAB MultiPower 460 Pulse. ESAB MultiPower 460 Pulse Instruction manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir

Indice de contenidos

Pagina 1 - Multipower 460PULSE

F-15-721-A 05/2003Multipower 460PULSEDC WELDING POWER SOURCESINSTRUCTION MANUALESAB ITEM NO. 0558002877, Multipower 460PULSE - 230/460/575 vac, 3 ph.,

Pagina 2 - USER RESPONSIBILITY

10levage, des câbles de grue ou divers cheminsélectriques.g. Empêchez l’apparition de toute humidité, notammentsur vos vêtements, à la surface de l’em

Pagina 3 - TABLE OF CONTENTS

11 Multi-process, three phase power source de-signed for heavy duty Industrial DC weldingapplications. Use for High Performance Mig, Pulse Mig, FluxCo

Pagina 4

12Options & Accessories:Remote Hand Control...0558002871This pendant provides remote output control and a contactorclosure

Pagina 5 - SECTION 1 SAFETY PRECAUTIONS

13Table 2-1. Specifications for Multipower 460PULSE2.0. GENERALBefore the Multipower 460PULSE power source is put into operation, thesafety section a

Pagina 6

14The Multipower 460PULSE is a multi-process power source designed for Migshort circuiting, spray and pulse spray transfer (GMAW), flux core (FCAW), T

Pagina 7

15Figure 2-3. Pulse Control PanelC. CONTROL PANEL DESCRIPTION (Refer to Figure 2-3 and 2-4)1. FAULT LAMPThe RED fault light on the Multipower 460PUL

Pagina 8

165. VOLTAGE/CURRENT TRIMThe arc voltage is controlled with this knob when the WELD PROCESSselector switch is in the MIG position. The Mig arc voltag

Pagina 9

17Figure 2-5. Multipower 460Main PowerOn/Off SwitchOutputConnectionsWire FeederConnectorRemote PendantConnectionContactor On/OffSwitchCircuit Breaker

Pagina 10

182. WIRE FEEDER CONTROL RECEPTACLEThis 19-pin receptacle (J1) accepts the control cable from the wire feederand handles all the control signals neede

Pagina 11 - How to Order:

19Table 3-1. Recommended Sizes for InputConductors and Line Fuses*Sized per National Code for 80 °C rated copper conductors @ 30 °C ambient. Notmore

Pagina 12 - Remote Hand Control

2These INSTRUCTIONS are for experienced operators. If you are not fully familiar with the principlesof operation and safe practices for arc welding a

Pagina 13

201. The primary power leads must be insulated copper conductors. Threepower leads and one ground wire are required. Either rubber coveredcable or co

Pagina 14

21SECTION 3 INSTALLATION5. Figures 3-3, 3-4 and 3-5 illustrate the input voltage terminal boards and the input voltage linkconnections. The particular

Pagina 15

22Table 3-2. Output Cable Sizes (Secondary)* Total cable length includes work and electrode cables. Cable size is based on directcurrent, insulated c

Pagina 16

234.0. OPERATIONA. WIRE FEEDER COMPATIBILITYThe Multipower 460PULSE power source can be used with several ESAB 42 voltwire feeders. The model wire

Pagina 17

24NOTE"OFF THE ARC" Wire Feeders can useeither MIG (CV) or STICK (CC) ProcessSelection. Place the contactor toggleswitch on the accesssory p

Pagina 18

25F. TIG WELDINGWhen the PROCESS switch is placed in the TIG position, the Multipower460PULSE is automatically set for CC (constant current) welding

Pagina 19 - SECTION 3 INSTALLATION

26When the WELD PROCESS switch ismoved to the TIG or STICK position,electrode becomes electrically“HOT”. Do not allow the electrode tocontact ground

Pagina 20

27When the WELD PROCESS switch ismoved to the TIG or STICK position,electrode becomes electrically“HOT”. Do not allow the electrodeto contact groun

Pagina 21

28The preprogrammed wire types, wire diameters and shielding gases arelisted in Table 4-2.The TRIM allows the operator to fine tune the pulse arc leng

Pagina 22

29The following procedure assumes the wire feed and voltage adjustments will bemade from the wire feeder front panel and wire and gas have been instal

Pagina 23 - SECTION 4 OPERATION

3TABLE OF CONTENTSSECTION TITLE PAGESECTION 1 SAFETY ...

Pagina 24 - PRESET PROCEDURE

30B. PULSE PROCESS CONTROL1. Use a tip-to-work distance (TTW) of 3/8" to 5/8". This refers to thedistance between the end of the Mig gun co

Pagina 25

31The selectable pulse parameters are any combination of WIRE TYPE or WIREDIAMETER selected using the PULSE SELECTION switches. Not all combina-tions

Pagina 26

32F. PULSE PARAMETERSTables 4-3 through 4-8 list the approximate pulse weld parameters for each materialand diameter available. These are provided fo

Pagina 27 - Carbon Arc Setup Procedure

33Table 4-3 Multipower 460PULSE Carbon Steel Data Table.035 Steel .040 SteelWFS Range (IPM)Pulse Peak (Amps)Pulse Width (ms)Pulse Back-ground (Amp

Pagina 28

34Table 4-4 Multipower 460PULSE Stainless Steel Data TableWFS Range (IPM)Pulse Peak (Amps)Pulse Width (ms)Pulse Back-ground (Amps)Pulse Frequency

Pagina 29

35Table 4-5 Multipower 460PULSE 4000 AluminumWFS Range (IPM)Pulse Peak (Amps)Pulse Width (ms)Pulse Back- ground (Amps)Pulse Frequency (Hz)WFS Range

Pagina 30

36Table 4-6 Multipower 460PULSE 5000 Aluminuml Data TableWFS Range (IPM)Pulse Peak (Amps)Pulse Width (ms)Pulse Back- ground (Amps)Pulse Frequency (

Pagina 31

37Table 4-7 Multipower 460PULSE Metal Core Carbon Steel Data Table.035 Metal Core CS .040 Metal Core CSWFS Range (IPM)Pulse Peak (Amps)Pulse Width (

Pagina 32

38Table 4-8 Multipower 460PULSE Metal Core Stainless Steel Data Table.035 Metal Core SS .040 Metal Core SSWFS Range (IPM)Pulse Peak (Amps)Pulse Widt

Pagina 33

39SECTION 5MAINTENANCEIf this power source does not op-erate properly, stop work imme-diately and investigate the causeof the malfunction. Maintenanc

Pagina 34

4TABLE OF CONTENTS

Pagina 35

40SECTION 5MAINTENANCE

Pagina 36 - NO PROGRAM

41TROUBLESHOOTINGSECTION 6DISCONNECT primary power at wallswitch, or circuit breaker, before at-tempting inspection or work inside thepower source.6.0

Pagina 37

42Multipower 460PULSE Wiring Diagram0558003034-BSECTION 6 TROUBLESHOOTING

Pagina 38 - 1/16 Metal Core SS

43Multipower 460PULSE Schematic Diagram (Sheet 1 of 3)0558003064-ASECTION 6 TROUBLESHOOTING

Pagina 39 - A. INSPECTION AND SERVICE

44Multipower 460PULSE Schematic Diagram (Sheet 2 of 3)0558003064-ASECTION 6 TROUBLESHOOTING

Pagina 40 - MAINTENANCE

45Multipower 460PULSE Schematic Diagram (Sheet 3 of 3)0558003064-ASECTION 6 TROUBLESHOOTING

Pagina 41 - 6.0. TROUBLESHOOTING

46SECTION 6 TROUBLESHOOTING

Pagina 42 - SECTION 6 TROUBLESHOOTING

47A. REPLACEMENT PARTSReplacement Parts are illustrated on the following figures. When ordering re-placement parts, order by part number and part nam

Pagina 43 - 0558003064-A

48124, 5678, 9151112, 131714Figure 7-1 - Front View, Multipower 460PULSE310161819SECTION 7 REPLACEMENT PARTS

Pagina 44

49SECTION 7 REPLACEMENT PARTSQTY. ITEM CIRCUITNO. REQ. NO. DESCRIPTION SYMBOL1 2 678025 Terminal Assembly2 1 952219 Outlet 110V (Square)3 1 952937 Co

Pagina 45

5WARNING: These Safety Precautions are foryour protection. They summarize precaution-ary information from the references listed inAdditional Safety In

Pagina 46

50123457QTY. ITEMNO. REQ. NO. DESCRIPTION SYMBOL1 3 99511916 Diode Fwd 200V 250A2 3 99511915 Diode Rev 200V 250A3 1 954864 Label 3 Pha

Pagina 47 - B. ORDERING

514621SECTION 7 REPLACEMENT PARTS

Pagina 48 - SECTION 7 REPLACEMENT PARTS

521234QTY. ITEMNO. REQ. NO. DESCRIPTION SYMBOL1 2 17280110 Res WW Fix'd ST 100W 5% 100.00 R3, R42 1 0558002712 Transformer 230/460/575V T13 12 6

Pagina 49

531234QTY. ITEM CIRCUITNO. REQ. NO. DESCRIPTION SYMBOL1 1 1312733 Label for Install Use COP Wire2 1 950219 Relief Strain 2" (Non-enclosed)3 1 672

Pagina 50

54126543QTY. ITEMNO. REQ. NO. DESCRIPTION SYMBOL1 1 952938 SCR 480V 18A Panel MNT2 1 951997 Transducer Current SH13 1 951085 SW THML D/T 176 15A 120V

Pagina 51

551265437SECTION 7 REPLACEMENT PARTS

Pagina 52

56 NOTES

Pagina 53

57 NOTES

Pagina 54

58 NOTES

Pagina 55

59 REVISION HISTORY1. 05/2003 - General editorial changes.

Pagina 56

6FUMES AND GASES -- Fumes andgases, can cause discomfort or harm,particularly in confined spaces. Donot breathe fumes and gases. Shield-ing gases can

Pagina 57

F-15-721-A 05/2003IF YOU DO NOT KNOW WHOM TO CALLTelephone: (800) ESAB-123/ Fax: (843) 664-4452/ Web:http://www.esab.comHours: 7:30 AM to 5:00 PM ESTA

Pagina 58

7ADVERTENCIA: Estas Precauciones deSeguridad son para su protección. Ellas hacenresumen de información proveniente de lasreferencias listadas en la se

Pagina 59

8HUMO Y GASES -- El humo y los gases,pueden causar malestar o daño,particularmente en espacios sin ventilación.No inhale el humo o gases. El gas de

Pagina 60 - F-15-721-A 05/2003

9a. Éloigner suffisamment tous les matériaux combus-tibles du secteur où l’on exécute des soudures ou descoupes à l’arc, à moins de les recouvrir com

Comentarios a estos manuales

Sin comentarios