SECTION 3 INSTALLATION
3.0. Installation
A. Location
A proper installation site is necessary for the power source to provide dependable service. A proper installation site permits
freedom of air movement through the unit while minimizing exposure to dust, dirt, moisture, and corrosive vapors. A mini-
mum of 18 inches (46 cm) is required between the side and rear panels of the power source and the nearest obstruction.
The selected site should also allow easy removal of the power source outer enclosure for maintenance. See Table 2-1 for
overall dimensions of the unit.
Do not use filters on this unit as they would restrict the volume of
intake air required for proper cooling. Output ratings on this unit
are based on an unobstructed supply of cooling air drawn over its
internal components. Warranty is void if any type of filtering device
is used.
CAUTION
B. Receiving, Unpacking And Placement
When requesting information concerning this equipment, it is essential that Item number, Serial number and Model number
of the equipment be supplied.
Upon receipt, remove all packing material and carefully inspect for any damage that may have occurred during
shipment. Any claims for loss or damage that may have occurred in transit must be filed by the purchaser with
the carrier. A copy of the bill of lading and freight bill will be furnished by the carrier on request.
Remove the power source from the container. Remove all packing materials. Check the container for any loose
parts.
Check air passages at front and rear of cabinet, making sure that packing material has not obstructed air flow
through the power source.
After selecting an installation site, place the power source in the desired location. The unit may be lifted either
by using the lifting bail or by forklift truck. If a forklift is used for lifting the unit, be sure that the lift forks are long
enough to extend completely under the base.