SECTION 4 OPERATION
Figure 4-5 Standard Mig Setup Procedure
1
3
2
4
.045
.040
.035
1/16
.052
WIRE TYPE
WIRE DIAMETER
PULSE SELECTION
EN-625 ERNiCrMo-3
STAINLESS
AL-4000
AL-5000
EN-60 ERNiCu-7
METAL CORE
STEEL
STEEL
EN-67 ERCuNi
0
5
4
3
2
1
9
8
7
6
Voltage (CV)
Current (CC)
Trim (Pulse)
TEMP
POWER
BLINKING
WIRE SPEED
OUT OF RANGE
STEADY
NO PROGRAM
PRESET
MIG
LIFT
START
TIG
STICK
REMOTE
PANEL
STANDARD
MIG PULSE
Auto Fan
Fan will cycle automatically
Multipower 460PULSE
WFS-IPM
A
AMPS
V
VOLTS
When the CONTACTOR switch is moved to the “ON” position, MP-460
Pulse output terminals and the cables connected to them become elec-
trically “HOT”. Do not allow the cable to contact ground potential.
CAUTION
F. Mig & Flux Core Welding Preset Procedure
When the PROCESS switch is placed in the MIG position, the MultiPower 460 Pulse is set for CV (constant voltage) weld-
ing for use with “Off the Arc” or Arc Voltage “ type wire feeders. With these feeders, power to run the wire feed motor
and accessories is suppied by the MP-460 Pulse output voltage. There is no contactor “ON” signal from the wire feeder to
tell the power source to turn “ON”. Therfore, the contatctor is turned “ON” manually to supply power to the wire feeder.
When the Mig gun trigger is pulled, wire feed begins and power is supplied to the gun through the secondary contactor
in the wire feeder unit. The following procedure assumes that the wire and gas have been installed.
Connect wire feeder to MultiPower 460 Pulse and set PANEL/REMOTE switch to PANEL position.
Set the STANDARD/MIG PULSE switch to the STANDARD position.
Place the WELD PROCESS switch in the MIG (center) position.
Press and release the PRESET button then turn the VOLTAGE to the approximate welding voltage needed for the
wire type and size to be used. If the MIG CONTACTOR is in the “ON” position the PRESET button must be held
down to preset the wire feed speed.
Flip the CONTACTOR switch on the MP-460 auxiliary panel to the “ON” position. See Fig. 4-6.
Turn the wire speed knob on the wire feeder to the desired wire feed speed.
Connect the work cable from the MP-460 and the voltage pick-up lead from the wire feeder to the part to be
welded.
Activate the gas purge switch if the wire feeder has this feature. If not, release the pressure roll so wire does not
feed. Pull the gun trigger and set the shielding gas flow rate by turning the adjustment knob on the shield gas
flowmeter to the recommended gas flow (typically 35 cfh).
Engage the drive stand pressure roll and begin welding by pulling the gun trigger. Trim the wire speed and volts